+49
Under review

Native CANopen support

Peter Bo 10 years ago in IQANdesign updated by River 2 months ago 10
Add dedicated CANopen channels to simplify implementation of CANopen communication. Also, support for EDS files would be nice.
+40
Under review

String functions

Gustav Widén (System support) 7 years ago in IQANdesign updated by Lars Bolduc 2 years ago 6

There are a few different forum questions and feature requests that I think would be possible to solve if we had added some string handling functions, for example comparison of text channel values: 

http://forum.iqan.se/topics/1006-any-way-to-store-serial-number/

http://forum.iqan.se/topics/403-convert-machine-id-to-numbers/

,string concatenation:

http://forum.iqan.se/topics/162-idea-ability-to-change-tp-channel-value-using-qcode/

and conversion from integer to text

http://forum.iqan.se/topics/863-ascii-characters-from-j1939-parameter/

Anyone else who thinks this could be a good idea?

+25

Ethernet/modbus communications protocols on MD4?

David Holcomb 9 years ago in IQANdesign updated by Andy 2 years ago 5

We frequently are integrating IQAN into larger systems that frequently have Ethernet/modbus in use.  Any hope of getting communication over the ethernet ports?

+17
Under review

Any plan to support importing EDS file?

Frank GUO 6 years ago in IQANdesign updated by Gustav Widén (System support) 1 year ago 4

Is there any plan to add importing EDS file into IQAN?

+18
Under review

Lamp feature for lables

Fredrik Forsberg 9 years ago in IQANdesign updated by Grisel, Evert-Jan 3 months ago 8

It would be nice to have lables with lamp function. Be able to define "Input channel", "ON color" and "OFF color" for lables.It would be easier than making two lables as we do now.

+15
Under review

Sub-Groups in Adjust Groups

Barth Hollanddrain 9 years ago in IQANdesign updated by Gustav Widén (System support) 1 year ago 9

Is it any way possible, or be made possible to create subgroups in the adjust-groups?
The applications we create use a lot of costumer-dependent values.

We use the MD4/5 screens on our machines, also to adjust values/parameters in the program.
Calibrating our systems takes a lot of time now, simply because of scrolling and searching for the right parameter.

Having sub-groups would speed things up.
Also having those subgroups optionaly password-protected would be a good addition.

+13

Touch screen slide finger option

Metalfor 9 years ago in IQANdesign updated by Gustav Widén (System support) 5 years ago 0


Hello again, thinking that we are in an era of smartphones applications, it would be interesting to have finger slide option to control objects movement in graphics.
Actually the "System Log" page called in "action" for a text button seems to has it. But the touch area defined by programmer to handle this is not available. Some images below. The last one is an example of how this feature would help to navigate through an alarm bar.
Regards. Diego.

Image 212

Image 213




Image 214

+12

CANopen and CANopen Safety in IQANdesign

Fredrik Forsberg 8 years ago in IQANdesign updated by Gustav Widén (System support) 6 years ago 1

Hello,


It would be nice if CANopen and CANopen Safety was implemented in IQAN Design.

We see the need of CANopen Safety as most of the suppliers for components such as CAN sensors are using or are planing to use CANopen Safety as the CAN-protocol for their safety related components (ISO 13849).


Today J1939 and Generic is implemented in IQAN Design. It would be nice if there was J1939, CANopen, CANopen Safety and Generic.


Regards

Fredrik Forsberg

+11

New System Information channel (SIC)

Jonas Bengtsson 8 years ago in IQANdesign updated by Ulrik Zakariasson (Software development) 8 years ago 0

Would it be possible to add a SIC that holds the filename used to program the system and also timestamp of the file?


It would help us a lot to keep track of versions, specials and machines.

I know there is Version under Project Properties but it happen to often it don't get updated.


+10
Under review

Ability to label CAN buses, Vref, etc in the List view of a master module

Edward Polzin 6 years ago in IQANdesign updated by Gustav Widén (System support) 6 years ago 1

I think it would be useful to be able to take the description text from the CAN bus, VRef, etc or add free text to the List view of a master module:


Image 1179



This would allow for clearer definition when sending to a wire harness builder or for troubleshooting.